Customization: | Available |
---|---|
Membrane Type: | Reverse Osmosis |
Type: | RO |
Still deciding? Get samples of US$ 356/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introduction
Perfect option for house-hold RO units with feed water lower than 2000ppm, like tap water, municiple water, underground water.
Features
Competitive pricing
certified quality
Excellent outlook and performance
Dry membrane
100% tested
Certificate: NF and ISO-9001
Data Sheet
Pressure (psi) |
Model | Rejection % | Average Permeate GPD (M3/day) |
150psi | ULP21-8040 | 99.0 | 11000 (41.6) |
ULP22-8040 | 99.0 | 12100(45.7) | |
ULP32-8040 | 99.5 | 10500(39.7) | |
ULP11-4040 | 98.0 | 2700(10.6) | |
ULP21-4040 | 99.0 | 2400(9.1) | |
ULP21-4021 | 99.0 | 950 (3.6) | |
ULP11-4021 | 98.0 | 1000 (3.78) | |
ULP21-2540 | 99.0 | 750 (2.84) | |
ULP21-2521 | 99.0 | 300 (1.13) | |
225psi | LP21-8040 | 99.5 | 9600 (36.3) |
LP22-8040 | 99.5 | 10500 (39.7) | |
LP21-4040 | 99.5 | 2400 (9.1) |
4040 industrial Ro membrane test report | ||||||||||
Time | pressure | original us | pure water us | pure water flow rate | wast water flow rate | temperature | Desalination rate | flow rate GPD | ||
10mins | 150psi | 1220 | 8.4 | 395L/H | 1800L/H | 29 degree | 99.31% | 2505.3 |